Effectiveness of heat and mass transfer on mixed convective peristaltic motion of nanofluid with irreversibility rate
|
Y Akbar,F M Abbasi,U M Zahid,S A Shehzad
|
|
|
Table 2. Comparison of $\phi ^{\prime} ({h}_{1})$ by using the Shooting method and the built-in function NDSolve in Mathematica.
|
|
Sc | ${\gamma }_{c}$ | Nt | Nb | Shooting method | NDSolve | Difference |
---|
0.2 | | | | 2.923 02 | 2.92303 | 0.000 01 | 0.4 | | | | 2.751 89 | 2.75188 | 0.000 01 | 0.6 | | | | 2.611 37 | 2.61138 | 0.000 01 | | 0.1 | | | 3.115 39 | 3.11540 | 0.000 01 | | 0.2 | | | 3.091 71 | 3.09172 | 0.000 01 | | 0.3 | | | 3.068 67 | 3.06868 | 0.000 01 | | | 0.2 | | 0.843 57 | 0.84358 | 0.000 01 | | | 0.4 | | 2.197 92 | 2.19793 | 0.000 01 | | | 0.6 | | 3.681 78 | 3.68179 | 0.000 01 | | | | 0.2 | 7.593 69 | 7.59370 | 0.000 01 | | | | 0.4 | 3.701 53 | 3.70154 | 0.000 01 | | | | 0.6 | 2.403 82 | 2.40383 | 0.000 01 |
|
|
|