Effectiveness of heat and mass transfer on mixed convective peristaltic motion of nanofluid with irreversibility rate
|
Y Akbar,F M Abbasi,U M Zahid,S A Shehzad
|
|
|
Table 3. Comparison of skin friction by using the Shooting method and the built-in function NDSolve in Mathematica.
|
|
Gt | Gc | Nt | Nb | Shooting method | NDSolve | Difference |
---|
0.5 | | | | −1.06618 | −1.06617 | 0.000 01 | 1.0 | | | | −0.73846 | −0.73845 | 0.000 01 | 1.5 | | | | −0.40594 | −0.40593 | 0.000 01 | | 0.0 | | | −1.01375 | −1.01374 | 0.000 01 | | 0.5 | | | −1.06618 | −1.06617 | 0.000 01 | | 1.0 | | | −1.11807 | −1.11806 | 0.000 01 | | | 0.2 | | −0.96284 | −0.96283 | 0.000 01 | | | 0.4 | | −1.03219 | −1.03218 | 0.000 01 | | | 0.6 | | −1.09966 | −1.09968 | 0.000 01 | | | | 0.2 | −1.32612 | −1.32611 | 0.000 01 | | | | 0.4 | −1.10898 | −1.10897 | 0.000 01 | | | | 0.6 | −1.03813 | −1.03812 | 0.000 01 |
|
|
|